Aqua Master Tools - E50 Replacement Electrode – High-Precision Modular Electrical Conductivity Combo Probe

Restore original factory telemetry, maintain absolute control over your fertilizer mixing channels, and eliminate unexpected equipment downtime with the Aqua Master Tools E50 Replacement Electrode. Purpose-built as the direct plug-and-play replacement sensor cartridge for the rugged E50 Digital EC & Temp Meter, this professional-grade component is engineered to handle the harsh, continuous-use conditions of commercial vertical indoor farms, high-volume greenhouse ranges, and industrial water testing lines. Over months of heavy exposure to concentrated nutrient solutions, hard water minerals, and balancing acids, all conductivity sensors naturally experience mineral crusting, terminal wear, and slowed reading responses. Instead of forcing you to throw away an entire digital tool, the smart modular engineering of the Aqua Master Tools ecosystem lets you simply swap out the worn probe cartridge. This replacement sensor features heavy-duty, fast-response conductivity rings paired with an integrated thermal sensor, feeding real-time electrical conductivity (EC) and fluid temperature data back to your digital screen instantly. The assembly is built with a heavy-duty, threaded compression collar and a premium rubber O-ring that creates a perfectly watertight seal, maintaining your meter's certified IP67 dust-tight and submersible floating rating. Pre-calibrated to integrate seamlessly with the E50's built-in 1-point automatic calibration system, this replacement probe slides into position without requiring specialized tools or manual rewiring, making it simple and cost-effective to keep your daily water testing rounds perfectly accurate cycle after cycle.


Best For: Routine seasonal maintenance for Aqua Master Tools E50 meters, replacing worn or fouled conductivity sensors, restoring slow meter response times, and maintaining essential backup inventory for commercial cultivation facilities.

Key Features & Technical Advancements

  • Dual-Function Integrated Sensor Array: Houses both the high-precision electrical conductivity rings and a fast-response thermal sensor inside a single, streamlined cartridge body.
  • Watertight Threaded Mechanical Interface: Engineered with an airtight locking sleeve and a durable rubber seal that maintains your meter's floating IP67 waterproof rating.
  • Rugged Non-Porous Shielding Shell: Encased in a heavy-duty polymer protective guard that shields the internal sensor elements from bumps against tank walls or hard mixing equipment.
  • Immediate Plug-and-Play Assembly: Built with precision connection pins that slide smoothly into the main E50 meter handle, completely cutting out hardwiring or specialized electrical tools.
  • Full 0 to 19.9 mS/cm Measurement Competency: Restores full-spectrum tracking, allowing your meter to register precise, real-time salt concentration changes in liquid fertilizers and runoff water.
  • High-Stiffness Contact Terminals: Outfitted with corrosion-resistant internal terminals that ensure steady, noise-free signal transfer to the digital processor for clean, uncompromised telemetry.

Product Technical Specifications Matrix

System, Mechanical, & Sensor Parameters Engineering Metric / Design Detail
Brand & Infrastructure Line Aqua Master Tools / Field Testing Replacement Series
Component Product Identity E50 Replacement EC & Temperature Electrode Cartridge
Target System Compatibility Exclusively Fits Aqua Master Tools E50 Combo Handheld Pen Meter
Electrical Conductivity Range 0 to 19.9 mS/cm Full-Spectrum Electrical Analysis
Solution Thermal Tracking Range 0°C to 50°C Operational Fluid Envelope
Sensor Reading Accuracy Capacity Restores Factory Baseline (± 2% EC Full-Scale | ± 0.5°C System Tolerances)
Interface Fitting Connection Multi-Pin Direct Socket with Threaded Heavy-Duty Compression Collar
Moisture Ingress Protection Rating Maintains Full IP67 Waterproof and Buoyant Floating Competency
Conductivity Sensor Architecture Heavy-Duty Corrosion-Resistant Metal Ring Electrodes with Temp Node
Recommended Calibration Fluid 1413 μS/cm (1.4 mS/cm) EC Standard Reference Solution

Advanced Sensor Conditioning & Substrate Control Tips

  • Executing a Full 1-Point Calibration Post-Installation: Every time you swap out a probe cartridge, you must re-align the meter's internal digital processor with the new sensor. Screw the fresh electrode tightly onto the E50 handle, then place the probe into clean 1413 μS/cm (1.4 mS/cm) calibration reference fluid and run the automatic calibration sequence. Once the screen locks in the reading, rinse the sensor with clean water before your first tank test to ensure your baseline accuracy across the board.
  • Root-Zone Hydration and Substrate Coordination: Keeping your testing equipment fresh ensures your liquid feeds match the specific substrate conditions your crops need to flourish. For optimal root health and fast nutrient uptake, combine your E50 measurements with a high-porosity 70/30 blend of Coco Coir and Horticultural Perlite. To maintain consistent moisture levels across large benches, route your nutrient solution through lines pressurized by a heavy-duty Plont PPH Submersible Pump managed by an automated digital shot-timer.
  • Safe Probe Cleaning and Maintenance Routines: Unlike pH probes, the conductivity elements on the E50 replacement electrode are robust metal rings that do not need to stay wet during storage. However, they must be kept totally free of fertilizer crusts, salt crystals, and oily organic residues. After finishing your water tests, rinse the sensor under clean tap water. If you notice salt build-up, soak the tip in specialized digital probe cleaner or isopropyl alcohol for a few minutes, then scrub gently with a soft brush to restore perfect electrical contact.
  • Executing Routine Facility Calibration Checks: To ensure your E50 holds its strict accuracy rating, calibrate the meter once every two weeks using fresh, unpolluted testing fluids. Pour a small amount of calibration liquid into a clean plastic cup, dip the sensor tip, and let the automatic 1-point calibration system auto-tune the meter back to true baseline. Always dump used calibration fluids rather than pouring them back into the main storage bottles to avoid contamination.

Ideal For (Uses)

  • Aqua Master Tools E50 Refurbishment: The ultimate direct repair option for commercial cultivation facilities and home growers who need to bring a slow or inaccurate E50 meter back to original factory-spec performance.
  • Hydroponic Reservoir Fertilizer Analysis: Perfect for indoor facility technicians running constant daily nutrient strength checks across liquid mixing tanks, reverse osmosis loops, and drain runoff arrays.
  • Commercial Facility Spare Parts Management: An exceptional backup component choice for commercial greenhouse operations and vertical farms looking to eliminate unexpected downtime by keeping extra replacement sensors on site.
Oversize Item Delivery

Oversized Item Delivery Options

Since oversized items require special handling, we may need to provide a custom freight quote for your order and will contact you with an updated shipping rate.

Available options include:

✔ Delivery to your closest depot for pickup - default method
✔ Direct delivery - requires forklift on site
✔ Direct delivery with tailgate lift truck (extra fees apply)
✔ Forklift loading at our warehouse (no extra charge if you arrange your own freight)
✔ Direct truck delivery (available in Victoria)

Important Notes:

  • Shipping costs vary by location and method
  • Because of the forklift requirement, delivery to the nearest depot is the default option and will be the method used unless you contact us to request otherwise.

Business Delivery:

  • Business delivery is available for commercial customers only
  • If you select business delivery and your products are bulky, it is your responsibility to ensure you have appropriate equipment (including forklifts) to unload products from the delivery truck
  • If you select business delivery and you are not a business, you risk your product not being delivered and may incur additional fees to retrieve your order
  • Business delivery customers must provide a valid business address and contact information
  • Additional fees may apply for failed delivery attempts due to lack of appropriate unloading equipment

Let us know your preference, and we'll arrange the best solution for you!

Shipping & Lead Times

Important Note on Availability & Shipping

Our warehouse serves as our office and logistics centre rather than a retail showroom. Because we ship from multiple locations and manage high-turnover stock, not all items are available for immediate pickup.

Lead Times:

  • In-Stock Items: Usually ready for dispatch the same day.
  • Supplier-Dependent Items: Usually take 2–8 weeks to arrive, depending on supplier availability. Products from Adloheat may take 8–12 weeks to manufacture—they are made to order in Australia by a small business, and longer lead times reflect the care put into quality.

While we strive for fast delivery, some timelines are subject to supplier availability and are beyond our control. We appreciate your patience as we source the best quality gear for your project.

Biosecurity & Interstate Shipping Restrictions

Due to strict state biosecurity regulations, we are unable to ship some products to certain states and territories:

  • Potting Mixes cannot be shipped to Western Australia (WA), the Northern Territory (NT), or Tasmania (TAS).
  • Seeds cannot be shipped to Western Australia (WA).

Orders placed for these items to restricted states will be cancelled and refunded. It is the customer's responsibility to ensure that the items being ordered can lawfully be delivered to their state or territory.

Price Match Guarantee

We Offer the Best Prices

We are committed to offering our customers the best prices possible. If you find the exact same product advertised at a lower price elsewhere, we invite you to contact us and we will review your price match request.

Price Match Conditions:

  • The competitor must be an Australian-based seller with a physical presence in Australia
  • The product must be the exact same item with a matching SKU or model number
  • The product must be in stock and available for purchase at the competitor
  • The lower price must be publicly advertised and currently available (not a clearance, closeout, or discontinued item)
  • Price matching excludes marketplace platforms including but not limited to Temu and Aliexpress
  • Price matching requests must be made before purchase

How to Request a Price Match:

To request a price match, please contact us at sales@greenhousepolytunnels.com.au with a link to the competitor's product listing, or call us on 0418 438 774. Please include the product details and the advertised lower price. We will review your request and respond within 2 business days.

Still Unsure?

Book an appointment with one of our team members. We are here to assist you every step of the way.