Aqua Master Tools High-Precision EC 1413 Calibration Solution (20mL Sachet) – Professional Temperature-Indexed Reference Buffer for Digital Conductivity Pens and Facility Monitors

$10.95
Add to Wishlist

Estimated delivery: 5 - 15 Business Days.

+5 days for regional locations on average [More Info]

visamasteramerican expressapple paygoogle payafterpay
SKU 4404
Barcode 8785278524633
Shipping Weight 0.05 kg
Description

Aqua Master Tools High-Precision EC 1413 Calibration Solution (20mL Sachet) – Professional Temperature-Indexed Reference Buffer for Digital Conductivity Pens and Facility Monitors

Lock in laboratory-grade telemetry accuracy and eliminate sensory reading drift across your digital monitoring infrastructure with the Aqua Master Tools High-Precision EC 1413 Calibration Solution. Explicitly formulated to meet the strict quality control standards of commercial indoor vertical farms, high-tech greenhouse operations, and automated fertigation systems, this professional-grade reference standard provides an uncompromised baseline for calibrating advanced electrical conductivity sensors. In high-intensity commercial cultivation, precise mineral dosing is everything. If an inline probe or handheld testing pen drifts even slightly out of calibration, it transmits false telemetry to your dosing brains, running the risk of under-feeding your crop or causing devastating root-zone salt burns. The Aqua Master Tools reference sachet completely resolves this risk. Containing 20mL of laboratory-verified, stable reference fluid, this single-use foil sachet protects the fluid from light, air, and evaporation, guaranteeing that the solution inside remains exactly 1413 μS/cm (or 1.41 EC) at the industry-standard 25°C validation point. By integrating these precise reference sachets into your facility's weekly standard operating procedures, you ensure your testing hardware reads your liquid environment with flawless accuracy shift after shift.


Pro Tip: Electrical Conductivity measurements are highly temperature-dependent. To ensure absolute calibration precision, your diagnostic hardware must account for fluid temperature fluctuations. Use the integrated temperature index printed on the packaging box to align your meter's target value with the exact temperature of your testing space.

Key Features & Technical Advancements

  • High-Memory Precision Formulations: Formulated to hit an exact, uncompromised reference point of 1413 μS/cm (1.41 EC) at 25°C, providing an ultra-reliable baseline for professional agricultural instrumentation.
  • Hermetically Sealed Single-Use Sachets: Packaged in a specialized 20mL light-blocking foil sachet that prevents air contamination and evaporation, guaranteeing fresh, laboratory-grade fluid purity every time it is opened.
  • Universal Hardware Compatibility: Engineered to work seamlessly with all major brands of analytical testing equipment, including Aqua Master Tools pens, Bluelab Truncheons, and automated inline dosing controllers.
  • Pre-Printed Temperature-Response Reference Chart: Outfitted with an on-foil temperature validation matrix, enabling technicians to double-check exact values when calibrating in un-insulated mixing rooms or cold greenhouses.
  • Completely Residue-Free Compound: Formulated with high-purity mineral salts that leave zero sticky films or crystal residues on delicate platinum or titanium electrode faces after a rinsing cycle.
  • Optimized Volume Packaging: The 20mL capacity provides the perfect liquid depth inside the sachet or a small decanting cup, allowing you to submerge pen-style electrodes fully without wasting fluid.

Product Technical Specifications Matrix

Calibration, Thermal, & Packaging Parameters Engineering Metric / Design Detail
Brand & Origin Aqua Master Tools / Engineered in the Netherlands
Primary Testing Focus High-Precision Accuracy Verification & Calibration of EC/CF/PPM Sensors
Standard Reference Value 1413 μS/cm | 1.41 EC | 706 PPM (500 Scale) | 989 PPM (700 Scale)
Standard Calibration Temperature 25°C (77°F) for Factory-Standard 1413 μS/cm Readout
Fluid Packaging Profile Hermetically Sealed, Light-Proof, Single-Use 20mL Foil Sachets
Sensor Compatibility Fit Digital EC Pens, Combos, Continuous Wall Monitors, and Dosing Probes
Chemical Formulation Safety Non-Hazardous, Pre-Mixed, Saturated Conductivity Standard
Primary Operational Benefit Eliminates Fertigation Drift, Prevents Over-Dosing, and Secures Logging Data

Thermal Variability & Reference Alignment Matrix

Because liquid electrical conductivity values shift predictably as fluid molecules heat up or cool down, your technicians must reference actual ambient fluid temperatures during a calibration procedure. Use this official data matrix to check your console's values if your room temperature deviates from 25°C:

Fluid Temp (°C) Target Value (μS/cm) Fluid Temp (°C) Target Value (μS/cm)
15°C 1147 24°C 1386
20°C 1278 25°C (Standard) 1413
21°C 1305 26°C 1440
22°C 1332 27°C 1467
23°C 1359 30°C 1548

Advanced Sensor Calibration & Substrate Control Tips

  • Execute a Thorough Sensor Pre-Wash Routine: Before introducing your sensor to the calibration fluid, unmount the probe and wash it with a dedicated electrode cleaner. Use a soft brush to clear away organic films and mineral scale from the metal pins, then rinse thoroughly with clean tap water.
  • Completely Dry the Probe Body and Pins: Shake off any excess rinse water clinging to the plastic casing. Use a clean, dry microfiber cloth to blot the probe body completely dry. Critical warning: never dip a wet probe directly into the calibration fluid, as residual water will dilute the sachet contents, instantly throwing off the 1413 μS/cm concentration and causing an inaccurate calibration.
  • Submerge and Align to Local Temperature: Tear open the Aqua Master Tools sachet along the dotted indicator line. Plunge your clean, dry conductivity pen or electrode lead straight into the liquid. Let it sit immersed for 60 to 90 seconds without pressing buttons to allow the probe's internal thermometer to reach thermal equilibrium with the fluid.
  • Lock the Display Value and Rinse: Check the current temperature readout on your meter. If your pen does not have automatic temperature compensation, check the chart above (e.g., if your fluid is at 22°C, adjust your manual calibration trim screw or button until the screen locks onto 1332). Press the calibration button until the console confirms the setting. Once saved, remove the probe, rinse it thoroughly in fresh water, and discard the used sachet.
  • Root-Zone Hydration and Substrate Coordination: Ensuring your EC wands and inline dosing loops are perfectly calibrated guarantees that your irrigation lines deliver exact nutritional curves, maintaining an ideal root environment. For optimal root health, accelerated nutrient absorption, and uncompromised drainage, route your verified fertilizer recipes into a high-porosity 70/30 blend of Coco Coir and Horticultural Perlite. To ensure completely uniform irrigation delivery across your entire layout, pressurize your feed lines using a heavy-duty Plont PPH Submersible Pump managed by an automated digital shot-timer.
  • The Single-Use Golden Rule: Never attempt to save open calibration fluid in a plastic bottle or jar for reuse next week. The second the high-purity fluid is exposed to open air, evaporation alters its water-to-salt ratio, and dust particles introduce minor contaminants. Reusing open fluid shifts the baseline concentration away from 1413 μS/cm, leading to drifted calibrations that skew your reservoir data logging. Always open a fresh sachet for every calibration cycle to guarantee true data tracking.

Ideal For (Uses)

  • Digital Conductivity Pen Calibration: The absolute standard calibration companion for field technicians utilizing handheld Aqua Master Tools EC pens or multi-parameter diagnostic sticks on the greenhouse floor.
  • Automated Fertigation Loop Audits: Ideal for commercial irrigation technicians who need to run weekly precision checks on continuous inline monitoring sensors to keep automated nutrient dosing systems tracking accurately.
  • Commercial Lab Compliance Logging: An exceptional data-verification choice for large-scale agricultural labs, commercial facilities, and research universities that require documented, single-use calibration checks to satisfy strict quality control procedures.
Oversize Item Delivery

Oversized Item Delivery Options

Oversized, heavy, and structural goods ship via specialist freight. Freight is calculated at checkout from estimated packaged volumetric or physical weight. Carrier depot audits may adjust the rate — if the increase exceeds 10%, we will contact you before processing.

Available options include:

✔ Delivery to your closest depot for pickup — default method
✔ Direct delivery — requires an operational forklift on site unless Tailgate Delivery has been specifically requested and quoted (contact us — this cannot be selected at checkout)
✔ Tailgate hydraulic lift delivery — must be specifically requested; contact us for a quote (not available as a checkout option; extra fees apply; required if you do not have a forklift)
✔ Forklift loading at our warehouse (no extra charge if you arrange your own freight)
✔ Direct truck delivery (available in Victoria)

Important Notes:

  • Shipping costs vary by location and method
  • Any carton or consignment over 25–30kg (or over 200cm) must be palletised
  • Without a specifically requested and paid Tailgate Delivery quote, palletised freight requires a forklift on site — otherwise the carrier will redirect to the nearest depot
  • Bulky and oversized items cannot be delivered to a PO Box — provide a physical street address
  • Failed deliveries, locked gates, unattended sites, or incorrect business/forklift declarations may incur carrier redelivery, demurrage, and restocking fees as set out in our Terms & Conditions

Business Delivery:

  • Selecting a business/commercial delivery rate warrants that the address has an operational forklift and certified operator during business hours
  • If the carrier cannot unload, the consignment may be redirected to a depot and secondary fees may apply
  • Additional fees may apply for failed delivery attempts due to lack of appropriate unloading equipment

See our Terms & Conditions (Article 8) for full freight and delivery rules.

Shipping & Lead Times

Important Note on Availability & Shipping

Our warehouse is a logistics hub, not a retail showroom. Listing a product online does not mean it is stored at our Thomastown warehouse — many lines ship from supplier hubs (split fulfilment may apply).

How lead times work:

  • Product page ETA: The Estimated Time of Arrival (ETA) / lead-time badge shown on the product page at checkout is the agreed delivery timeframe for that order under Australian Consumer Law.
  • Metro baselines: Advertised ETAs apply to standard metropolitan zones. Regional and remote addresses may take longer and may attract surcharges.
  • Peak seasons: Orders in March–May, August–October, EOFY (June), Black Friday/Cyber Monday (November), and Christmas/New Year (December–January) may automatically add a 2–4 week buffer beyond the product page ETA.
  • Supplier-dependent / backordered items: If stock is delayed, we will notify you with a revised ETA. You then have 7 days to accept the new timeframe or cancel for a full refund.
  • Adloheat: Custom-made products from Adloheat (Pakenham, VIC) may take 4–12 weeks depending on the order.

Full fulfilment, cancellation, and freight rules are in our Terms & Conditions.

Biosecurity & Interstate Shipping Restrictions

Due to strict state biosecurity regulations, we are unable to ship some products to certain states and territories:

  • Potting Mixes cannot be shipped to Western Australia (WA), the Northern Territory (NT), or Tasmania (TAS).
  • Seeds cannot be shipped to Western Australia (WA).

Orders placed for these items to restricted states will be cancelled and refunded. It is the customer's responsibility to ensure that the items being ordered can lawfully be delivered to their state or territory.

Price Match Guarantee

We Offer the Best Prices

We are committed to offering competitive market rates. If you find an identical, currently stocked product advertised at a lower price by an authorised Australian competitor, contact us before purchase and we will review your request.

Price Match Conditions:

  • The competitor must be a registered Australian business (active ABN) with a physical trading address or verified commercial presence in Australia
  • The item must be identical in brand, model, SKU, gauge, dimensions, and specifications
  • The lower price must be publicly advertised in AUD, currently active, and available for immediate purchase
  • Excludes liquidation, clearance, closeouts, damaged goods, and discontinued lines
  • Excludes overseas marketplaces and aggregators including Temu, AliExpress, eBay auction sellers, and Amazon third-party sellers
  • Excludes trade quotes, bulk discounts, and custom negotiated quotes not publicly visible
  • Requests must be made in writing before purchase

How to Request a Price Match:

Email [email protected] with a live link or official quote. We reserve sole discretion to verify and approve price match adjustments. See Article 6.7 of our Terms & Conditions.

Pricing Errors & 105% Store Credit

If a displayed price is incorrect due to a website error or an extraordinary supplier increase, we will contact you before processing. You may proceed at the corrected price, choose an alternative, or cancel for a full cash refund. A 105% store credit may be offered as a courtesy bonus at our sole discretion only. It is not an entitlement, and we may refuse it if we believe it is being abused or sought in bad faith. Full details: Terms & Conditions Article 6.1.

Still Unsure?

Book an appointment with one of our team members. We are here to assist you every step of the way.