Aqua Master Tools - P50 Replacement Electrode – High-Sensitivity Modular Glass Combo Probe
Please note the above shipping is an estimation only. Actual shipping cost can be calculated on the checkout page.
Important shipping notice: This product is not stocked at our Thomastown, VIC warehouse and is dispatched from another local warehouse. Please allow approximately 1-2 weeks for it to reach us before it is ready for pickup or dispatch.
Aqua Master Tools - P50 Replacement Electrode – High-Sensitivity Modular Glass Combo Probe
Restore original factory precision, protect your crucial nutrient monitoring schedules, and extend the working life of your handheld testing gear with the Aqua Master Tools P50 Replacement Electrode. Purpose-built as the direct mechanical and electrical swap-out cartridge for the rugged P50 Digital pH & Temp Meter, this professional-grade sensor probe is engineered to handle the tough conditions of commercial indoor vertical farms, industrial greenhouse facilities, and high-volume water filtration plants. Over months of constant contact with concentrated fertilizers, chemical acids, and hard water minerals, all digital meter probes naturally experience slow sensor drift, sluggish tracking, and general glass membrane degradation. Instead of forcing you to throw away an entire digital tool, the smart modular engineering of the Aqua Master Tools ecosystem allows you to simply replace the worn sensor cartridge. This high-sensitivity probe features a custom-engineered, fast-response glass bulb array paired with an integrated thermal sensor, feeding real-time fluid acidity and solution temperature telemetry back to your digital screen instantly. The plug-and-play assembly is built with a heavy-duty, threaded locking collar that creates a perfectly watertight seal, maintaining the meter’s certified IP67 dust-tight and submersible rating. Pre-calibrated to integrate flawlessly with the P50's built-in 2-point automatic calibration system, this replacement probe slips into place without requiring specialized tools or manual rewiring, making it cost-effective and simple to keep your water testing rounds perfectly accurate cycle after cycle.
Best For: Routine seasonal maintenance for Aqua Master Tools P50 meters, replacing worn or cracked glass probes, restoring slow meter response times, and maintaining essential backup inventory for commercial cultivation facilities.
Key Features & Technical Advancements
- Dual-Function Integrated Sensor Array: Houses both the high-precision chemical pH glass bulb and a fast-response thermal sensor inside a single, streamlined cartridge body.
- Watertight Threaded Mechanical Interface: Engineered with a heavy-duty rubber O-ring and an airtight locking sleeve that maintains your meter's floating IP67 waterproof rating.
- Premium Non-Porous Shielding Shell: Encased in a rugged polymer protective housing that shields the fragile internal reference junctions from bumps against tank walls or hard equipment.
- Immediate Plug-and-Play Assembly: Built with precision connection pins that slide smoothly into the main P50 meter handle, completely cutting out hardwiring or specialized tools.
- Full 0.1 to 14.0 pH Measurement Competency: Restores full-spectrum tracking, allowing your meter to register precise, real-time chemical changes in liquid fertilizers and runoff water.
- High-Stiffness Contact Terminals: Outfitted with corrosion-resistant internal terminals that ensure steady, noise-free signal transfer to the digital processor for clean, uncompromised telemetry.
Product Technical Specifications Matrix
| System, Mechanical, & Sensor Parameters | Engineering Metric / Design Detail |
|---|---|
| Brand & Infrastructure Line | Aqua Master Tools / Field Testing Replacement Series |
| Component Product Identity | P50 Replacement pH & Temperature Electrode Cartridge |
| Target System Compatibility | Exclusively Fits Aqua Master Tools P50 Combo Handheld Pen Meter |
| Chemical Acidity Tracking Range | 0.1 to 14.0 pH Full-Spectrum Target Analysis |
| Solution Thermal Tracking Range | 0°C to 50°C Operational Fluid Envelope |
| Sensor Reading Accuracy Capacity | Restores Factory Baseline (± 0.1 pH | ± 0.5°C System Tolerances) |
| Interface Fitting Connection | Multi-Pin Direct Socket with Threaded Heavy-Duty Compression Collar |
| Moisture Ingress Protection Rating | Maintains Full IP67 Waterproof and Buoyant Floating Competency |
| Primary Sensor Glass Matrix | Low-Impedance Spherical pH Glass Membrane with Built-In Temp Node |
| Recommended Storage Environment | Must Be Stored with 3M KCI Electrode Storage Solution in Protective Cap |
Advanced Sensor Conditioning & Substrate Control Tips
- Hydrating and Activating Your Fresh Electrode: Brand-new replacement probes are shipped dry or with a small moisture sponge to protect them during transit. Before using your new P50 electrode for the first time, you must activate the glass sensing membrane. Pour a small amount of specialized KCI Electrode Storage Solution into the protective cap, stand the meter upright, and let the tip soak for at least 2 to 4 hours. This conditions the glass bulb, ensuring fast response times and stable, accurate readings on your first test.
- Root-Zone Hydration and Substrate Coordination: Keeping your testing equipment fresh ensures your liquid feeds match the specific substrate conditions your crops need to flourish. For optimal root health and fast nutrient uptake, combine your P50 measurements with a high-porosity 70/30 blend of Coco Coir and Horticultural Perlite. To maintain consistent moisture levels across large benches, route your nutrient solution through lines pressurized by a heavy-duty Plont PPH Submersible Pump managed by an automated digital shot-timer.
- Executing a Full 2-Point Calibration Post-Installation: Every time you swap out a probe cartridge, you must re-align the meter's internal digital processor with the new sensor. Screw the fresh electrode tightly onto the P50 handle, then place the probe into clean pH 7.0 calibration reference fluid and run the automatic calibration sequence. Once the meter locks in the neutral point, rinse the tip with clean water and repeat the step in pH 4.0 reference fluid to secure your baseline accuracy across the board.
- Safe Cleaning and Longevity Storage Protocols: Never touch the glass bulb at the bottom of the electrode with your bare fingers or paper towels, as skin oils and abrasive materials can easily scratch or ruin the delicate sensing surface. If fertilizer salts form on the tip, rinse it under warm tap water or soak it in a specialized cup of digital probe cleaner. Always store the electrode with a few drops of storage solution inside the cap, keeping the probe tip constantly moist to prevent premature sensor failure.
Ideal For (Uses)
- Aqua Master Tools P50 Refurbishment: The ultimate direct repair option for commercial cultivation facilities and home growers who need to bring a slow or inaccurate P50 meter back to original factory-spec performance.
- Hydroponic Reservoir Water Analysis: Perfect for indoor facility technicians running constant daily acid-base checks across liquid fertilizer tanks, reverse osmosis lines, and drain runoff arrays.
- Commercial Facility Spare Parts Management: An exceptional backup component choice for commercial greenhouse operations and vertical farms looking to eliminate unexpected downtime by keeping extra replacement sensors on site.
Oversized Item Delivery Options
Since oversized items require special handling, we may need to provide a custom freight quote for your order and will contact you with an updated shipping rate.
Available options include:
✔ Delivery to your closest depot for pickup - default method
✔ Direct delivery - requires forklift on site
✔ Direct delivery with tailgate lift truck (extra fees apply)
✔ Forklift loading at our warehouse (no extra charge if you arrange your own freight)
✔ Direct truck delivery (available in Victoria)
Important Notes:
- Shipping costs vary by location and method
- Because of the forklift requirement, delivery to the nearest depot is the default option and will be the method used unless you contact us to request otherwise.
Business Delivery:
- Business delivery is available for commercial customers only
- If you select business delivery and your products are bulky, it is your responsibility to ensure you have appropriate equipment (including forklifts) to unload products from the delivery truck
- If you select business delivery and you are not a business, you risk your product not being delivered and may incur additional fees to retrieve your order
- Business delivery customers must provide a valid business address and contact information
- Additional fees may apply for failed delivery attempts due to lack of appropriate unloading equipment
Let us know your preference, and we'll arrange the best solution for you!
Important Note on Availability & Shipping
Our warehouse serves as our office and logistics centre rather than a retail showroom. Because we ship from multiple locations and manage high-turnover stock, not all items are available for immediate pickup.
Lead Times:
- In-Stock Items: Usually ready for dispatch the same day.
- Supplier-Dependent Items: Usually take 2–8 weeks to arrive, depending on supplier availability. Products from Adloheat may take 8–12 weeks to manufacture—they are made to order in Australia by a small business, and longer lead times reflect the care put into quality.
While we strive for fast delivery, some timelines are subject to supplier availability and are beyond our control. We appreciate your patience as we source the best quality gear for your project.
Biosecurity & Interstate Shipping Restrictions
Due to strict state biosecurity regulations, we are unable to ship some products to certain states and territories:
- Potting Mixes cannot be shipped to Western Australia (WA), the Northern Territory (NT), or Tasmania (TAS).
- Seeds cannot be shipped to Western Australia (WA).
Orders placed for these items to restricted states will be cancelled and refunded. It is the customer's responsibility to ensure that the items being ordered can lawfully be delivered to their state or territory.
We Offer the Best Prices
We are committed to offering our customers the best prices possible. If you find the exact same product advertised at a lower price elsewhere, we invite you to contact us and we will review your price match request.
Price Match Conditions:
- The competitor must be an Australian-based seller with a physical presence in Australia
- The product must be the exact same item with a matching SKU or model number
- The product must be in stock and available for purchase at the competitor
- The lower price must be publicly advertised and currently available (not a clearance, closeout, or discontinued item)
- Price matching excludes marketplace platforms including but not limited to Temu and Aliexpress
- Price matching requests must be made before purchase
How to Request a Price Match:
To request a price match, please contact us at sales@greenhousepolytunnels.com.au with a link to the competitor's product listing, or call us on 0418 438 774. Please include the product details and the advertised lower price. We will review your request and respond within 2 business days.
Shop
- Choosing a selection results in a full page refresh.


